A new 40ft HC Reefer Pharma-Suitable factory-fitted with a Thermo King Magnum Plus refrigeration unit. The setpoint range of -40°C to +30°C covers frozen biologics, deep-frozen pharmaceutical products, standard cold-chain vaccine and biopharmaceutical storage, controlled room temperature ambient storage, and chilled product ranges. The container configuration — food-grade stainless steel interior, insulated shell, panic alarm, and inside-openable safety door — provides the base technical specification for pharmaceutical cold chain fit-out subject to buyer’s validation.
Important: This container is supplied as a pharmaceutical-suitable base specification. Use in TGA-regulated pharmaceutical storage, GMP-compliant cold chain, clinical trial investigational medicinal product (IMP) logistics, or GDP-regulated distribution requires Installation Qualification (IQ), Operational Qualification (OQ), Performance Qualification (PQ), calibrated continuous temperature monitoring with audit trail, and applicable compliance documentation to be arranged and completed by the buyer’s qualified persons. See Compliance & Buyer Responsibility below.
Refrigeration Specifications
| Refrigeration unit | Thermo King Magnum Plus |
| Compressor type | Digital scroll with aluminized coating |
| Temperature range | -40°C to +30°C setpoint |
| Refrigerant | R452A (low-GWP HFO blend) |
| Power supply | 460V / 3-phase, 30A circuit |
| AUS grid compatibility | Voltage transformer required for 415V 3-phase supply |
| Power cable | ~15 m (50ft) included |
Container Body & Interior
| Container type | New 40ft HC ISO reefer, one-trip |
| Outer cladding | Marine-grade stainless steel (MGSS) |
| Interior walls | Stainless steel — food-grade |
| Interior liner | Aluminium scuff liner |
| Insulation | High-density polyurethane throughout walls, roof, and floor |
| Floor | Aluminium flat floor — pallet and trolley compatible |
| Floor drains | 4 × automatic self-closing drains (2 front, 2 rear) |
| Door curtain | Heavy-duty sliding thermal curtain |
| Safety door | Openable from inside — for manned cold storage |
| Interior lighting | LED interior light with dedicated switch |
| Panic alarm | Exterior siren and strobe light |
40ft HC Reefer Pharma-Suitable Dimensions
External
| Length | 12,192 mm (40′ 0″) |
| Width | 2,438 mm (8′ 0″) |
| Height | 2,896 mm (9′ 6″) — High Cube |
Internal (after insulation panels)
| Length | 11,582 mm (38′ 0″) |
| Width | 2,286 mm (7′ 6″) |
| Height | 2,591 mm (8′ 6″) |
Door Opening
| Width | 2,286 mm (7′ 6″) |
| Height | 2,540 mm (8′ 4″) |
Weight
| Tare weight | 4,500 kg (9,920 lbs) |
| Payload capacity | 29,500 kg (65,040 lbs) |
Temperature Range Coverage
The -40°C to +30°C setpoint range technically covers all standard pharmaceutical storage classifications. Actual performance at each setpoint is subject to ambient temperature conditions, cargo load, door opening frequency, and site-installed validation.
| Pharmaceutical Storage Class | Temperature Requirement | Setpoint Coverage |
|---|---|---|
| Deep Frozen (biologics, mRNA products) | −40°C | At minimum setpoint (validation required) |
| Frozen Pharmaceutical | −20°C to −15°C | Within setpoint range |
| Cold Chain (vaccines, insulin, biologics) | +2°C to +8°C | Within setpoint range |
| Controlled Room Temperature | +15°C to +25°C | Within setpoint range |
| Ambient | Up to +30°C | At maximum setpoint |
40ft HC Reefer Pharma-Suitable Key Features
- One-trip condition — new container body, first cargo voyage only
- Thermo King Magnum Plus refrigeration unit
- -40°C to +30°C setpoint range
- Digital scroll compressor — precision temperature control
- Food-grade stainless steel interior walls
- Marine-grade stainless steel exterior cladding
- High-density polyurethane insulation throughout
- 4 automatic self-closing floor drains — washdown-friendly
- Panic alarm with exterior siren and strobe — personnel safety
- Safety door openable from inside — required for manned cold storage
- R452A refrigerant — low global warming potential HFO blend
- ~15 m (50ft) power cable included
- Built to ISO 668 Series 1 dimensional standards
Suitable For (Subject to Buyer’s Validation)
- Pharmaceutical cold chain fit-out — base container platform for buyer’s validation program
- Vaccine and biopharmaceutical storage — subject to buyer’s temperature mapping and monitoring installation
- Clinical trial cold chain — subject to sponsor’s validation package
- Veterinary biological storage — subject to APVMA compliance for regulated products
- Hospital and health service medical supply cold storage — subject to health service compliance
- Emergency management cold-chain stockpiles
- Commercial food-grade cold storage (non-regulated use)
Compliance & Buyer Responsibility — Read Before Ordering
This container is supplied as a new one-trip refrigerated container with the technical specification suited to pharmaceutical cold chain fit-out. It is not supplied with pharmaceutical validation documentation, temperature mapping certification, or GxP compliance packages. Use in regulated pharmaceutical storage or distribution requires the following to be arranged and delivered by the buyer’s qualified persons before regulated product is stored:
- Installation Qualification (IQ) — verification that unit installation matches design and manufacturer specifications at the buyer’s site
- Operational Qualification (OQ) — verification that the unit performs to specification across intended operating range and ambient conditions
- Performance Qualification (PQ) — verification that the unit maintains required temperature across representative load and use scenarios
- Temperature mapping — full three-dimensional temperature mapping under empty and loaded conditions per Australian GDP guidance
- Continuous temperature monitoring — calibrated data logger or continuous monitoring system with audit trail, alarms, and reporting
- Calibration and re-calibration schedule — for all temperature-critical sensors
- Quality Management System (QMS) — SOPs for operation, deviation management, alarm response, and maintenance
- TGA compliance — for TGA-regulated products, the buyer’s storage and distribution activity must meet the TGA’s Good Distribution Practice (GDP) guidance and applicable licensing
- Site electrical connection — voltage transformer (415V to 460V) required for AUS grid connection; installation by licensed electrician
ASCS supplies the container and manufacturer’s warranty on the container structure and refrigeration unit. Site-based validation, monitoring, and regulatory compliance are the buyer’s responsibility. Consult with a pharmaceutical quality consultant or qualified person (QP) before purchase if this is your first regulated cold chain installation.
Warranty
Supplied with a manufacturer’s warranty on both the container structure and the Thermo King refrigeration unit. Contact us for current warranty terms, coverage period, and claim process before order confirmation.
Browse the full refrigerated container range for standard food-grade reefer, blast freezer, and used cargo-worthy configurations.